Lennox Furnace Error Codes

Lennox furnaces with a digital ignition control show E-codes. E250 is an open limit (often a dirty filter or blocked airflow), E270 is a lockout after repeated failed ignition, E228 is a pressure switch calibration failure (venting), and E241 means flame was sensed out of sequence, so shut off the gas and call a pro. ML180 furnaces use LED flash codes instead.

Smell gas, or your CO alarm sounds? Leave the house and call your gas utility or 911 from outside. Don’t try to diagnose it.

Which models this covers

Lennox EL296UHV and SL280UHV furnaces with ignition control 103130 (E-codes, Unit Information 1125 and SL280UHV instructions 508245), and ML180UHE furnaces with ignition controls 103217 and 107163 (flash codes, Unit Information 1120). Other Lennox models may differ. Codes differ between control boards, so check the code chart printed on your unit or in its manual if your model isn’t listed.

How to read the code

Read the code on the control board display through the furnace door window, or count the LED flashes on ML180 models (fast flashes, then a 3-second pause). Lennox lists these as technician diagnostics. The homeowner checks below are common, safe starting points.

E-codes (EL296UHV / SL280UHV)

CodeWhat it meansWhat to do
E200Hard lockout: rollout circuit open or was openCall a pro. A rollout trip can mean a blocked flue or cracked heat exchanger.Pro
E201Lost communication with indoor blower motorCall a pro.Pro
E223Low pressure switch failed openCheck outdoor vent pipes for snow, ice or blockage. If clear, call a pro.Pro
E228Unable to calibrate pressure switch (inducer calibration failure)Check vent pipes for blockage. Otherwise, call a pro to check venting and switch wiring.Pro
E241Flame sensed out of sequenceShut off the gas to the furnace and call a pro (possible gas valve leak).Pro
E250Limit circuit open (airflow, blockage or firing rate)Replace a dirty filter and open closed vents. It retries after a 1-hour lockout. If it repeats, call a pro.Pro
E270Soft lockout: maximum ignition retries, no flame currentCheck the gas is on. If it repeats, call a pro (often the flame sensor or igniter).Pro
E290Igniter circuit fault (1-hour soft lockout)Call a pro.Pro
E291Restricted airflowReplace a dirty filter and make sure vents and returns aren’t blocked.
E292Blower motor can’t start (obstructed wheel or seized bearings)Call a pro.Pro

ML180 LED flash codes

CodeWhat it meansWhat to do
1Reversed line polarityCall a pro or electrician.Pro
2Improper groundCall a pro or electrician.Pro
3Burner failed to light, or lost flameCheck the gas is on. If it repeats, call a pro.Pro
4Low flame signalCall a pro. The flame sensor often needs cleaning.Pro
5Watchguard lockout (retries/recycles exceeded)Reset power. If it repeats, call a pro.Pro
7Primary limit openReplace a dirty filter and open vents. If it repeats, call a pro.Pro
8Rollout switch openCall a pro.Pro
9Pressure switch failed to close, or openedCheck vent pipes for blockage. Otherwise, call a pro.Pro
10Pressure switch opened 5 times in one heat cycleCheck vent pipes for blockage. Otherwise, call a pro.Pro
11Pressure switch stuck closedCall a pro.Pro
12Flame sensed without gas valve energizedTurn off the furnace and call a pro.Pro
13Low line voltageCall a pro or electrician.Pro

Sources

These codes are transcribed from the manufacturer’s own documentation. Many websites repeat codes that don’t match the manuals, so when in doubt, trust the chart on your unit.

Code pointing to a big repair? Check whether to repair or replace before you pay for it.

Frequently asked questions

What does E228 mean on a Lennox furnace?

E228 means the control couldn’t calibrate the pressure switch during inducer startup. Lennox points to venting and pressure switch wiring. Check the outdoor vent pipes for blockage, then call a pro. It isn’t a low-voltage code, as some sites claim.

What does E250 mean on a Lennox furnace?

E250 means the limit circuit opened because the furnace overheated, usually from restricted airflow. Replace a dirty filter and open closed vents and returns. The furnace retries after a 1-hour lockout. If it keeps happening, call a pro.

What does E270 mean on a Lennox furnace?

E270 is a soft lockout after the maximum number of ignition attempts with no flame detected. Make sure the gas is on. A recurring E270 usually means a dirty flame sensor, weak igniter or gas supply problem that a pro should check.